Difference between revisions of "timeout"
Jump to navigation
Jump to search
m |
|||
(3 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
''For console command, see [[timeouts.txt]].'' | ''For console command, see [[timeouts.txt]].'' | ||
− | + | == [[:Category:Self Condition|Self Conditions]] == | |
− | |||
; timeout [<seconds>] | ; timeout [<seconds>] | ||
Line 8: | Line 7: | ||
− | + | == Console Command == | |
+ | ;timeout (<timeout key>) [<seconds>] | ||
+ | |||
+ | :<timeout key> | ||
+ | ::- a timeout key name from timeouts.txt. | ||
− | + | :<seconds> | |
− | : | + | ::- the time in seconds. |
− | == | + | :Set a timeout. |
+ | {| class="wikitable" border="1" cellspacing="0" | ||
+ | |-style=background-color:#F9F9F9; | ||
+ | !Command | ||
+ | !Description | ||
+ | |- | ||
+ | |align=center|timeout <timeout key> | ||
+ | |Display the current value of specified key name. | ||
+ | |- | ||
+ | |align=center|timeout <timeout key> <seconds> | ||
+ | |Set a new value for the specified key name. | ||
+ | |} | ||
− | |||
− | |||
− | |||
− | : | + | == [[EventMacro#Parameters|Parameter]] of the automacro eventMacros: == |
+ | {{Template:Timeout}} | ||
[[Category:Self Condition]] | [[Category:Self Condition]] | ||
[[Category:Console Command]] | [[Category:Console Command]] | ||
+ | [[Category:EventMacro_Automacros]] | ||
+ | [[Category:EventMacro_Parameters]] |
Latest revision as of 22:34, 26 April 2021
For console command, see timeouts.txt.
Self Conditions
- timeout [<seconds>]
- If this option is set, wait for the specified number of seconds before using the block again.
Console Command
- timeout (<timeout key>) [<seconds>]
- <timeout key>
- - a timeout key name from timeouts.txt.
- <seconds>
- - the time in seconds.
- Set a timeout.
Command | Description |
---|---|
timeout <timeout key> | Display the current value of specified key name. |
timeout <timeout key> <seconds> | Set a new value for the specified key name. |
Parameter of the automacro eventMacros:
- timeout <number>
-
- timeout is an optional parameter.
- timeout defines the time in seconds before this automacro can activate again after an activation.
- If not used in the automacro the default value will be used, which is: 0.
- Must have a numeric value.
automacro <automacro name> { <automacro conditions and parameters (and only them)> timeout 60 call myMacro } macro myMacro { <macro instructions (and only them, as this is regular macro)> log This macro will only be called every 60 seconds }